PM-02 3para Patient Monitor
Features
- 7 inch high resolution color TFT LCD display.
- Real time S-T segment analysis, pace-maker detection.
- Indication of Incorrect manipulation and malfunction analysis.
- Patient info input management function.
- Multi-lead ECG waveforms display in phase.
- Large volume of tabular and graphic trends information storage and easy to recall.
- Capture dynamic waveforms.
- Efficient resistance to interference of defibrillator and HF knife.
- UP to 4 hours working capacity of built-in rechargeable lithium battery.
- Unique accessory management cabinet.
- Networking capacity.
- Optional: IBP
STANDARD: SpO2, TEMP, NIBP, ECG
TECHNICAL SPECIFICATIONS
ECG Specification
Lead Configuration
- Standard 3 - Lead or 5 - Lead
- 3-Lead RA LA, LL, Lead Method : |, Il
- 5-Lead RA, LAL. RL, V,
- Lead Method : 1 Il, aVR, aVL, aVF, V
Increase
- 250, 500, 1000, 2000
HR
- Range
- Adult 15 - 300bpm (beat / minute)
- Neonatal baby children 15 - 350 bpm (beat / minute)
- Precision 1% or #1bpm, the larger prevails
- Resolution 1 bpm (beat / minute)
Sensitivity
- > 200 uV (Peak(o-peak value)
Input Impedance
- > 5 (megohm)
Bandwidth
- Diagnostic mode 0.05 - 130Hz
- Monitoring Mode 0.5- 40Hz
- Operation mode 1-20Hz
Operation mode 1-20Hz
- Diagnostic mode > 90 dB
- Monitoring Mode > 100 dB
- Operation mode > 100 dB
Pole Polarization Voltage Range
- 300mV
Pacing Pulse Test
- Test pacing pulse in accordance with the following conditions:
- Amplitude: 2mV - 700mV
- Width: 0.1ms -2ms
- Risetime: 10us - 100us
Pacing pulse inhibition
- When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
- Amplitude: 2mV 700mV
- Width 0.1ms - 2ms
- Risetime 10us - 100us
Baseline Recovering Time
- After defibrillation < 3 seconds
Signal Range
- 8 mV (Peak - to - peak value)
Calibrating Signal
- 1mV (Peak-to-peak value), precision 5%
ST Segment Measuring Volume
- Measuring range : -2.0mV - +2,0mV
- Measuring precision : Ranging -0.8 mV - +0.8mV, measuring error is 0.02mV or 10%. The larger prevails. No definition for other ranges.
RESP Specification
- Measuring Method
- RA-LL impedance
RESP Impedance Measuring Range
- 0.3-3
Base Impedance Range
- 200-4000
Bandwidth
- 0.1-2.5Hz
RESP Rate
- Range
- Adult: 0-120 BrPM
- Children and neonatal baby: 0-150 BrPM
- Resolution: 1 BrPM
- Precision: 2 BrPM
Asphyxia Alarm
- 10-40 seconds
SpO2 Specification
SpO2
- 0.3-3
- Range: 0-100%
- Resolution: 1%
-
Precision: 70-100% 2 DIGIT
0%-69% no definition given
PR
- Range: 20-300bpm
- Resolution: 1bpm
- Precision: 3bpm