PM-01 5para Patient Monitor
Features
- 12.1 inch High resolution Color TFT LCD display.
- Real time S-T segment analysis, pace-maker detection.
- Indication of Incorrect manipulation and malfunction analysis.
- Patient info input management function.
- Multi-lead ECG waveforms display in phase.
- Large volume of tabular and graphic trends information storage and easy to recall.
- Capture dynamic waveforms.
- Efficient resistance to interference of defibrillator and HF knife.
- UP to 2 hours working capacity of built-in rechargeable battery.
- Unique accessory management cabinet.
- Networking capacity.
- Optional: IBP, ETCO2 and 2-1BP
STANDARD: ECG, NIBP, SpO2, RESP, TEMP, PR/HR
TECHNICAL SPECIFICATIONS
ECG Specification
Lead Configuration
- Standard 3 - Lead or 5 - Lead
- 3-Lead RA LA, LL, Lead Method : |, Il
- 5-Lead RA, LAL. RL, V,
- Lead Method : 1 Il, aVR, aVL, aVF, V
Increase
- 250, 500, 1000, 2000
HR
- Range
- Adult 15 - 300bpm (beat / minute)
- Neonatal baby children 15 - 350 bpm (beat / minute)
- Precision 1% or #1bpm, the larger prevails
- Resolution 1 bpm (beat / minute)
Sensitivity
- > 200 uV (Peak(o-peak value)
Input Impedance
- > 5 (megohm)
Bandwidth
- Diagnostic mode 0.05 - 130Hz
- Monitoring Mode 0.5- 40Hz
- Operation mode 1-20Hz
Operation mode 1-20Hz
- Diagnostic mode > 90 dB
- Monitoring Mode > 100 dB
- Operation mode > 100 dB
Pole Polarization Voltage Range
- 300mV
Pacing Pulse Test
- Test pacing pulse in accordance with the following conditions:
- Amplitude: 2mV - 700mV
- Width: 0.1ms -2ms
- Risetime: 10us - 100us
Pacing pulse inhibition
- When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
- Amplitude: 2mV 700mV
- Width 0.1ms - 2ms
- Risetime 10us - 100us
Baseline Recovering Time
- After defibrillation < 3 seconds
Signal Range
- 8 mV (Peak - to - peak value)
Calibrating Signal
- 1mV (Peak-to-peak value), precision 5%
ST Segment Measuring Volume
- Measuring range : -2.0mV - +2,0mV
- Measuring precision : Ranging -0.8 mV - +0.8mV, measuring error is 0.02mV or 10%. The larger prevails. No definition for other ranges.
RESP Specification
- Measuring Method
- RA-LL impedance
RESP Impedance Measuring Range
- 0.3-3
Base Impedance Range
- 200-4000
Bandwidth
- 0.1-2.5Hz
RESP Rate
- Range
- Adult: 0-120 BrPM
- Children and neonatal baby: 0-150 BrPM
- Resolution: 1 BrPM
- Precision: 2 BrPM
Asphyxia Alarm
- 10-40 seconds
NIBP Specification
Measuring Method
- Pulse wave oscillometry
Work Mode
- Manual/Automatic / STAT
Measuring Interval of Automatic Measuring Mode
- 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
- 5 minutes
PR range
- 40-240 bpm
Measuring Range and Precision
- Range
Adult:
- Systolic blood pressure 40-270mmHg
- Diastolic blood pressure 10-215mmHg
- Mean blood pressure 20-235mmHg
Children:
- Systolic blood pressure 40-200mmHg
- Diastolic blood pressure 10-150mmHg
- Mean blood pressure 20-165mmHg
Neonatal baby:
- Systolic blood pressure 40-135mmHg
- Diastolic blood pressure 10-100mmHg
- Mean blood pressure 20-110mmHg
- Static pressure range 0-300mmHg
- Static pressure precision 3mmHg
Pressure Precision:
-
Max. average error: 5mmHg;
Max. Standard deviation: 8mmHg
Overvoltage Protection
- Adult mode 300 mmHg
- Children mode 240 mmHg
- Neonatal baby mode 150 mmHg
SpO2 Specification
SpO2
- 0.3-3
- Range: 0-100%
- Resolution: 1%
-
Precision: 70-100% 2 DIGIT
0%-69% no definition given
PR
- Range: 20-300bpm
- Resolution: 1bpm
- Precision: 3bpm
TEMP Specification
Suitable for Temperature Sensor
- YSI series, CYF series
Channel Quantity
- Channel Quantity
Measuring
- Range: 0-50C
- Resolution: 0.1C
- Precision: 0.1C (excluding sensor error)
IBP
- Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
- ART: 0-300 mmHg
- PA: -6-120 mmHg
- CVP/RAP/LAP/ICP: -10-40 mmHg
- P1/P2: -10-300 mmHg
Press Sensor
- Sensitivity: 5 uV/V/mmHg
- Impedance: 300-3000
- Resolution: 1 mmHg
- Accuracy: 2% or 1mmHg, whichever is greater
- Actualization interval: about 1 Sec.